Pour les spécialistes du tamisage : avec l'AS 200 jet pro et l'AS 200 jet pharma conforme aux normes GMP, les équipes de laboratoire disposent d'une tamiseuse tout-en-un peu encombrante et conviviale.
Tamisage, pesage et évaluation à l'aide d'un seul appareil : la combinaison d'un tamisage à jet d'air de pointe et d'une balance intégrée garantit une analyse granulométrique précise et fiable en un temps record. Le logiciel AS 200 jet pro intégré via l'écran tactile assure des processus intelligents avec une facilité d'utilisation maximale.
To celebrate the launch of the AS 200 jet pharma we are giving away two machines!
Tout ce dont vous avez besoin pour utiliser l'AS 200 jet pro / pharma est un aspirateur industriel externe. Vous trouverez ici les aspirateurs adaptés :
The balance, which has been integrated into the machine design for the first time, is extremely robust – and patented in this setting! You can even use a rubber hammer to loosen any material that sticks to the lid during sieving without affecting the accuracy of the balance.
The integration of the balance not only saves additional space in your laboratory but also reduces errors. There is no need to transfer material between the sieving machine and an external balance, which effectively prevents material loss. Thanks to a high weighing readability of 0.01 g, all necessary data are recorded precisely during sieving, and the respective particle size is evaluated using the integrated software.
The air jet sieving process:
✔ eliminates the need for additional mechanical sieving aids
✔ protects the sample material through individual selection of pressure, speed and height of the used sieve
✔ enables short sieving times (typically 2-3 minutes per process)
Dans le cadre de la surveillance des équipements de test, vous pouvez calibrer la tamiseuse (horloge, capteur de vitesse et de pression) et la balance interne. Dans le cadre du service de maintenance RETSCH, nous nous chargeons volontiers de tous les processus de calibration pour vous.
"Even when using the new AS 200 jet pharma for the first time, you immediately notice how well thought-out and user-friendly it is. I am particularly impressed by the guided sieving: the clear step-by-step instructions practically eliminate errors caused by omitted steps.
The integrated, robust balance is a real plus—it makes handling noticeably easier and saves valuable space in the laboratory, as an external balance is no longer necessary. Additional safety features such as the Weighing-Assistant, Backweigh-Tolerance, and trend analysis ensure even greater process reliability in our everyday laboratory work.”
Dr. Michael Ostendorf, Senior Expert Particle Technology/Science Fellow, Bayer AG
Thanks to native software integration, you always have control over the entire process chain via an intuitive touch display:
✔ Sieve Management ✔ Parameter Setup ✔ Method Setup ✔ Sieve Analysis | ✔ Weighing ✔ Data Evaluation & Reporting via USB or LAN connection ✔ Optional User Management (in the pharma version) |
The patented combination of sieving and weighing in the AS 200 jet pro offers you real added value.
The principle behind this: for sieving, the sieving chamber is connected airtight to the vacuum cleaner. For a precise weighing process, the airtight sieving chamber is mechanically decoupled.
Your advantage in everyday laboratory work: error-free, time-saving weighing and subsequent evaluation in a single process, without the hassle of transferring the sieve between the machine and the balance.
Not only existing customers benefit from our modular and sustainable development design. The AS 200 jet pro allows the use of all RETSCH test sieves with a diameter of 203 mm (8") and 200 mm (with adapter) and a height of 25 and 50 mm (1" and 2").
With the integrated software, you can easily perform both simple routine sieving and complex distribution analyses: and display all results immediately afterwards in both graphical and tabular form.
Assurez-vous que le tamis d'essai correspond à la méthode sélectionnée et identifiez vos échantillons en scannant simplement le code-barres correspondant ! Grâce à un lecteur de codes-barres USB standard et à l'option Sieve-Check (Controle des tamis), vous pouvez vérifier la compatibilité entre la méthode sélectionnée et le tamis d'essai requis. Cela réduit le risque d'erreurs à long terme.
Determining adequate sample quantities is a real time-consuming task, especially when dealing with different sample materials in series.
Thanks to the new Weighing-Assistant in the AS 200 jet pro, this problem is now a thing of the past. After entering the respective sample bulk density, the system recommends a sieve-specific weighing range. This allows you to meet the specifications for the maximum permissible sieve load and the required minimum quantity in equal measure – and avoid incorrect sieving!
This function allows you to set your own parameters for your individual weighing processes. First, specify the sample quantity to be weighed. Then you can define define deviation tolerances as upper and/or lower limit in percent. Compared to the Weighing-Assistant (which refers to general standards), a narrower process-related loading range can be specified—tailored precisely to your needs.
Votre échantillon respecte-t-il les limites de qualité prédéfinies ? Grâce à la tolérance de pesée, vous pouvez vous assurer que la taille des particules et leur distribution répondent à vos exigences.
Les écarts par rapport aux spécifications apparaissent immédiatement sous forme de message à l'écran, ce qui vous garantit une fiabilité encore plus grande du processus !
Trend analysis can be used to compare several sieving processes based on freely selectable parameters. This allows you to benefit from simple and reliable monitoring of various quality criteria.
Detect early on when your sieves are no longer functioning in accordance with standards and need to be replaced.
Replace the often purely subjective assessments with objective measurement data that realistically reflects the current condition of your sieve. Trend analysis allows changes in sieve quality to be detected and faulty sieves to be replaced at an early stage. For certified sieve testing we offer the Retsch calibration service.
Monitor production processes change by continuously comparing multiple sieving processes. This allows you to identify potential changes in ongoing processes at an early stage and make immediate adjustments.
The internal wizard guides the user step by step through the entire process. Every process step is clearly explained and ensures reliable sieve processes. Human errors are reduced to a minimum.
The optional “Weighing Assistant” recommends a suitable sample amount which avoids errors based on overcharging the sieve but still keeping a minimum amount for a reliable sieve analysis by considering the sample’s representativeness.
The “Weighing Assistant” exclusively can be used with RETSCH test sieves and can easily be activated/deactivated in the method.
The AS 200 Jet Pharma is a separate model adapted to the needs of the pharmaceutical industry and other regulated environments. It offers all the functions of the AS 200 Jet Pro and has several additional features.
The AS 200 jet pharma variant offers you all the functions you need to meet the requirements of modern particle size analysis in accordance with GMP guidelines.
The system meets the software validation requirements according to
✔ ISPE GAMP 5
✔ FDA 21 CFR Part 11
✔ EC GMP Annex 11
for fulfilling with the highest standards in quality assurance.
The user management ensures complete transparency and security through the optional assignment of hierarchical access rights and passwords, as well as the setup of legally compliant e-signatures.
To make it even easier to meet internal or GMP requirements, a comprehensive documentation package is available as an option.
This includes
✔ Qualification Master Plan (QMP)
✔ Risk Analysis (FMEA)
✔ Installation Qualification (IQ)
✔ Operational Qualification (OQ)
The documents are customized for your company and make initial setup easier for you.
With the optional high-performance cyclone, even extremely fine particles can be recovered without significant pressure loss during the sieving process. In addition, the use of a cyclone helps to extend the service life of the vacuum cleaner filter.
Optionally, you can easily connect your existing, qualified balance as an external device via USB. The internal software already offers factory-installed connection options for the most common balances.
Air jet sieving is the optimal method for dry sieving of samples with a high proportion of fine particles. Compared to traditional sieving methods, this process saves time and reduces your costs in the long term.
✔ As an alternative to vibration screening, this method offers a significantly higher process speed for fine particle sizes.
✔ Unlike other methods, air jet sieving uses only one sieve per sieving process.
Guided Sieving: After selecting the desired sieving method, the software guides you step by step through the sieving process. You can precisely control all relevant parameters via the control panel of the AS 200 jet pro. In addition, Guided sieving improves safety, as each step is clearly described, thereby reducing human error.
The following evaluation data is available as standard. A complete list, functions, and the underlying formulas can be found in our knowledge base:
and much more. |
In addition, further comparisons, limit value monitoring, and trend analyses can be generated.
La tamiseuse à jet d'air AS 200 jet pro / pharma de RETSCH est parfaitement adapté pour la séparation, le fractionnement et la granulométrie des matériaux pharmaceutiques, de la céramique, des produits chimiques, des cosmétiques, des produits alimentaires, des minéraux, des pigments, des plastiques, des revêtements en poudre, du caoutchouc, des particules de toner et des poudres à laver.
produits pharmaceutiques
Charbon
plastiques
Sucre
ciment et minéraux
Consultez notre base de données d'applications pour trouver la meilleure solution pour votre application.
L'AS 200 jet pro / pharma est équipé d'une buse à fente rotative, sur laquelle sont placés le tamis et le couvercle. Un vide génère un puissant jet d'air qui fait tourbillonner les particules d'échantillon sur le tamis et les répartit. Les échantillons dont la taille est inférieure à celle des mailles du tamis sont transportés par le flux d'air inverse vers le cyclone ou l'aspirateur. Le jet d'air assure également la désagrégation continue des particules agglomérées (désagglomération) et le nettoyage des mailles du tamis.
Applications | séparation, fractionnement, détermination de la granulométrie |
Champ d'application | aliments, chimie / plastiques, environnement / recyclage, géologie / métallurgie, matériaux de construction, médecine / pharmacie, verre / céramiques, ... |
Matière chargée | poudres |
Plage de mesure* | 10 µm - ~ 4 mm |
Mouvement de la matière à tamiser | dispersion par jet d'air |
Typical. batch / feed capacity | 0.3 - 100 g |
Nombre max. de fractions | 1 (en utilisant un cyclone: 2) |
Touch screen | Yes with 10.1“ display |
Vitesse de rotation | digital, 5 – 80 min-1 (nozzle) |
Time display | digital, 00:30 – 15:00 min |
Integrated balance | Yes, with reading accuracy 0.01 g and calibration accuracy 0.1 g |
Vide | 2,000-6,500 Pa / 20-65 mbar / 0.3-0.95 psi |
Digital parameter setting | Yes, software included, pro or pharma version |
Storable SOPs | More than 40, depends only on storage capacity |
Connectivity | Yes, 2 x USB, Ethernet |
Mode de fonctionnement intermittent | non |
Vide | 2,000 - 9,999 Pa / 20 - 99 mbar / 0.3 – 1.45 psi |
Convient pour le tamisage à sec | oui |
Convient pour le tamisage en milieu humide | non |
Avec certificat de contrôle / calibrable | oui |
Diamètres des tamis utilisables | 203 mm (200 mm avec adaptateur) |
Hauteur max. de la colonne de tamis | 1 tamis (25 mm (1") / 50 mm ( 2")) |
Accessoires | cyclone / external optional high precision balance |
Donnée d'alimentation électrique | 100-240 V, 50/60 Hz |
Connexion d'alimentation | monophasé |
L x H x P | 516 x 180 x 404 |
Poids net | ~ 17 kg |
Normes | CE |
Graphical User Interface, guided sieving | oui |
Mode of operation | Fast sieving, manual sieving and methods |
Languages | German and English |
Parameter units changeable | Size: mm/µm/mesh/inch Mass: g/kg Time: s/min Pressure: mbar/Pa/psi Volume: ml/cl/l/cm3 |
SOPs | Yes, integrated in methods, more than 40 |
Individual sample labelling | Yes, for each sample, reference to method during data choice and in overview |
Parameter setting per test sieve | oui |
LIMS ready | oui |
Teamviewer online support | oui |
Screenshot function | oui |
Use of different vacuum cleaners | Machine can train any phase angle controllable vacuum cleaner, adaption required |
Back-up function | oui |
Automatic storage of results | Yes, in machine, auto report function, PDF document or to printer |
Results shown, as table or graphs | oui |
Different diagram types (linear or logar.) | Yes, log/lin, log/log, lin/lin for x and y axis |
Different diagram types | Cumulative, RRSB, Histogram, density, residual distribution |
Calculation of individual dx values | More than 10 |
Label naming | ISO (q3/Q3/1-Q3/p3) or descriptive (density/total distribution/residual distribution/percent) |
Overlay of results | Yes, up to 10 Curves, tables and overview |
Individual scalable diagrams | Yes, via zoom in or via setting of max. axis value |
Highest precision thanks to | Sieve-Check function, Plausibility test, Weighing-Assistant and Weigh-in tolerance, Calculation option for density, Filter function for sieve rows, TrendAnalysis for sieves and methods, Backweighing-Tolerance |
Yearly calibration service | Yes, optional |
Connection of external balance (optional) | oui |
Standard balance driver | Yes, scale management for external scales, communication protocols for specific scales Kern, Sartorius, Mettler are stored. |
Connectivity | Connection to barcode scanners, printer, mouse and keypad |
Software validation | ISPE GAMP 5, EC GMP Annex 11 conform, AuditTrail acc. to FDA 21 CFR part 11 |
User management | Yes, free configurable levels, individual rights option for each user |
Role and password management | oui |
Audit-trail with E-signature | oui |
Enforce audit trail comments | oui |
Generation/Export of user lists and daily reports | oui |
Restore | oui |
Sous réserve de modifications techniques et d'erreurs